Filtration Membrane Discs
Thin, precut membrane rounds for high-throughput, fast filtration of liquid and gas samples. Gridded and non-gridded discs. Various materials including mixed cellulose ester, polycarbonate, PTFE, nylon, and PVDF. For air monitoring/analytical research.
Sizes
Filter membranes are made in a range of diameters, typically designed to fit a specific holder or manifold.
Materials
Filter membrane can be made from cellulose, mixed cellulose esters (MCE), polyvinylidene fluoride (PVDF), polyethersulfone (PES), polyvinyl chloride (PVC), polytetrafluoroethylene (PTFE), nylon, polycarbonate (PC), polyester, polyethylene terephthalate (PET), and polypropylene (PP). Other membrane materials include aluminum oxide, gelatin, porcelain, and glass.
Pore Size
The size of membrane pores determines which particles will be retained by the filter. A pore size of 0.2 µm is small enough to remove microbes from solutions; a 0.45 µm ore size can remove larger particulates.
Color and Grids
White membrane filters may be plain or marked with square grids (outlined in black) that can help with enumerating particles. Gridded or plain black membrane filters may be helpful when filtering light-colored particulates.
Sterility
Filter membranes may be pre-sterilized or may be sterilized using ethylene oxide, gamma irradiation, or autoclaves. The need for sterility is determined by the application, which are many and varied:
- Light microscopy samples
- Cytology sample preparation
- Electron microscopy samples
- Air quality and other environmental monitoring
- Water analysis and water quality testing
- Microbiology colony counting and quality control
- Chemotaxis
- Sterile preparation of buffers, tissue culture media, microbiological media, and other biological fluids
- (11)
- (1)
- (1)
- (99)
- (8)
- (150)
- (9)
- (1)
- (8)
- (4)
- (6)
- (195)
- (1)
- (3)
- (22)
- (76)
- (185)
- (51)
- (129)
- (1)
- (1)
- (46)
- (14)
- (95)
- (18)
- (2)
- (22)
- (26)
- (6)
- (1)
- (4)
- (3)
- (4)
- (4)
- (11)
- (18)
- (8)
- (55)
- (145)
- (64)
- (3)
- (40)
- (226)
- (46)
- (18)
- (28)
- (8)
- (111)
- (31)
- (20)
- (56)
- (1)
- (32)
- (2)
- (13)
- (4)
- (1)
- (16)
- (1)
- (6)
- (25)
- (28)
- (1)
- (1)
- (2)
- (80)
- (5)
- (1)
- (1)
- (36)
- (1)
- (1)
- (809)
- (147)
- (1)
- (1)
- (3)
- (1)
- (3)
- (1)
- (390)
- (309)
- (6)
- (3)
- (136)
- (630)
- (59)
Filtered Search Results
MilliporeSigma™ Omnipore™ Membrane Filters, 0.2 μm
Hydrophilic PTFE polymer membrane filter compatible with virtually all solvents, acids, and alkaline solutions. Omnipore™ Membrane Filters are biologically and chemically inert.
| Pore Size | 0.2 μm |
|---|---|
| Flow Rate | >2.6 mL/min x cm2 |
| Wettability | Hydrophilic |
| Type | Filter Membranes |
| Color | White |
| No. per Case | 100Pack |
| Quantity | 100/Pk. |
| Material | PTFE |
| Filter Type | Screen Filter |
| Hydrophobicity | Hydrophilic |
| Autoclavable | Not Autoclavable |
| Sterility | Non-sterile |
MilliporeSigma™ MF-Millipore™ Membrane Filter, 0.1 μm
13 mm diameter, mixed cellulose esters (MCE) membrane, hydrophilic
| Thickness (Metric) | 105 μm |
|---|---|
| Pore Size | 0.1 μm |
| Flow Rate | 1.5 mL/min x cm2 |
| Wettability | Hydrophilic |
| Type | Filter Membranes |
| Color | White |
| Material | MCE |
| Autoclavable | Not Autoclavable |
| Sterility | Non-sterile |
MilliporeSigma™ MF-Millipore™ Membrane Filter, 3 μm
Mixed cellulose esters (MCE) membrane, hydrophilic
| Pore Size | 3.0 μm |
|---|---|
| Flow Rate | 320 mL/min x cm2 |
| Wettability | Hydrophilic |
| Type | Filter Membranes |
| Color | White |
| Material | MCE |
| For Use With (Application) | For use in air monitoring; Fluid monitoring; Particle collection and analysis; QC of fluid holding tanks. |
| Autoclavable | Not Autoclavable |
| Sterility | Non-sterile |
MilliporeSigma™ Isopore™ Membrane Filters, 0.1 μm
Use for analyses of airborne contaminants and other particles using optical or electron microscopy. Isopore™ Polycarbonate Membrane Filters have a smooth, glass-like surface for clearer sample observation. Available in a variety of pore sizes/flow rates, diameters and colors.
| Pore Size | 0.1 μm |
|---|---|
| Wettability | Hydrophilic |
| Type | Filter Membranes |
| Color | White |
| Material | Polycarbonate |
| Filter Type | Screen Filter |
| Autoclavable | Not Autoclavable |
| Sterility | Non-sterile |
MilliporeSigma™ S-Pak™ Sterile Membrane Filter Kit
Made from mixed esters of cellulose and have been optimized for MF method microbiological analysis of water or other liquids
| Pore Size | 0.5 μm |
|---|---|
| Diameter (Metric) | 47 mm |
| Color | White |
| For Use With (Application) | For microbiological analysis |
| Sterility | Sterile |
MilliporeSigma™ Isopore™ Membrane Filters, 2 μm
Use for analyses of airborne contaminants and other particles using optical or electron microscopy. Isopore™ Polycarbonate Membrane Filters have a smooth, glass-like surface for clearer sample observation. Available in a variety of por
| Flow Rate | Avg. 180 mL/min x cm2 (typical results (at 10 psi);932 mL/min x cm2/psi) |
|---|---|
| Wettability | Hydrophilic |
| Type | Filter Membranes |
| Color | White |
| No. per Case | 100Pack |
| Quantity | 100/Pk. |
| Material | Polycarbonate |
| Filter Type | Screen Filter |
| Hydrophobicity | Hydrophilic |
| For Use With (Application) | Air Analysis; Cell Biology; Cell Culture; Bioassays; Cytology; Environmental Analysis; Epifluorescence. |
| Autoclavable | Not Autoclavable |
| Sterility | Non-sterile |
MilliporeSigma™ LCR Hydrophilized PTFE Membrane Filters
Filtration of aqueous fluids with no wetting
| Pore Size | 0.45 μm |
|---|---|
| Color | White |
| No. per Case | 100Pack |
| Quantity | 100/Pk. |
| Material | Polycarbonate |
| Hydrophobicity | Hydrophilic |
| For Use With (Application) | Clarification of acids, bases, and cryogenic fluids; Clarification of propellants; Analysis of hydraulic fluids; RNA isolation; Clarification of aqueous or organic solutions prior to chromatographic analysis |
| Sterility | Non-sterile |
| Thickness (Metric) | 0.14 mm |
| Bubble Point | 9 to 13.2 psi |
| Flow Rate | 60 mL/min x cm2 |
| Wettability | Hydrophilic |
| Type | Filter Membranes |
| Filter Type | Screen Filter |
| Autoclavable | Not Autoclavable |
MilliporeSigma™ Durapore™ Membrane Filters, 0.1 μm
Durapore™ Membrane Filters are recommended when maximum recovery is important.
| Pore Size | 0.1 μm |
|---|---|
| Type | Filter Membranes |
| Color | White |
| Material | PVDF |
| Filter Type | Screen Filter |
| Autoclavable | Not Autoclavable |
| Sterility | Non-sterile |
Sartorius Gridded Sterile Cellulose Nitrate Membrane Filters: 0.45μm
Ensure quality control in microbiological filtering. Sartorius Gridded Sterile Cellulose Nitrate Membrane Filters, 0.45μm are single-packed membranes with colored grids for colony counting, particle testing and microscopy. The 0.45μm pore size is made in accordance with ISO 7704. Choose from two diameters and quantities in a range of filter/grid color combinations.
| Pore Size | 0.45 μm |
|---|---|
| Disposable | Single-use |
| Format | Disc |
| Material (Membrane) | Cellulose Nitrate |
| Individually wrapped | Yes |
| Material | Cellulose Nitrate |
| Hydrophobicity | Hydrophilic |
| For Use With (Application) | For colony count; sterility testing; particle count; microscopy |
| Sterility | Sterile |
Cytiva Whatman™ 0.8 μm Pore Size (ME 27) Mixed Cellulose Ester Membranes, Plain
Whatman™ (ME 27) Mixed Cellulose Ester Membranes, Plain are particularly effective in applications requiring higher flow rates and larger volume filtration including clarification or sterilization of aqueous solutions, particulate analysis and removal, air monitoring, and microbial analysis.
| Pore Size | 0.8 μm |
|---|---|
| Bubble Point | 1.3 bar |
| Flow Rate | 2.8 sec./100 mL/12.5 cm⊃ (at Δp = 0.9 bar) |
| Material (Membrane) | ME 27 |
| Grid Color | Plain |
| Material | MCE |
| Surface Type | Plain |
| For Use With (Application) | Filtration, cytology, air monitoring, aqueous HPLC samples, biological assays |
| Autoclavable | Autoclavable |
| Sterility | Non-sterile |
| Gas Flow Rate | 11.6 sec./100 mL (at Δp = 3 mbar) |
Sartorius Microsart™ @Filter 100 in Trays
Membrane filters suitable for use in the Microsart @Filter units
| Disposable | Single-use |
|---|---|
| Format | Disc |
| Diameter (Metric) | 47 mm |
| Material | Cellulose Nitrate |
| Sterility | Sterile |
Cytiva Nucleus Membrane
Made from polycarbonate film, for precision analysis of track-etched manufacturing
| Type | Nucleus Membrane |
|---|---|
| Material | Polycarbonate |
| For Use With (Application) | Air Analysis, Bioassay, Cell Biology, Environmental Analysis, Epi-Fluorescence Microscopy, EPA Test, Fuel Test, Parasitology, and Underwater Microbiology |
MilliporeSigma™ Fluoropore™ Membrane Filter, Pore Size: 5 μm
Unlike fibrous filter media that trap particles in their matrix, Fluoropore™ membranes collect particles on their surface. For use in airborne particle monitoring applications.
| Pore Size | 5.0 μm |
|---|---|
| Flow Rate | 122 mL/min x cm2 |
| Wettability | Hydrophobic |
| Type | Screen Filter |
| Material (Membrane) | Fluoropore |
| Material | PTFE |
| Filter Type | Screen Filter |
| Hydrophobicity | Hydrophobic |
| Autoclavable | Autoclavable |
| Sterility | Non-sterile |
Cytiva Whatman Cyclopore Polycarbonate Membrane
Featuring sharp cut-off and reproducible microfiltration characteristics of track-etched membrane filters
| Material | Polycarbonate |
|---|
Cytiva Whatman™ Anodisc™ Filter Membranes
Constructed with precision pore structure and narrow pore size distribution. Whatman™ Anodisc™ Filter Membranes ensure a high level of particle removal efficiency. Captures microorganisms and particulates on the surface of the membrane for subsequent analysis.
| Material | Aluminum Oxide |
|---|